Updated over 11 years ago by Knödlseder Jürgen
This page summarizes analysis results obtained using GammaLib on the Crab.
The interface has been validated using the COMPTEL data from Viewing Period 1. This observation was a 14 days pointing on the Crab. The analysis has been performed using GammaLib-00-07-00. The background has been modeled using a Phibar-fitted DRG file. This is only a crude background model, which may explain the discrepancy between nominal and fitted fluxes. The quoted sensitivities and the sensitivity derived by multiplying the statistical uncertainty by a factor of 3 are pretty close. Units are ph/cm2/s.
Energy | Nominal flux (1) | Fitted flux | Error | Quoted sensitivity (2) | Sensitivity (3*error) |
0.7-1 MeV | 5.55e-4 | 8.55e-4 | 5.80e-5 | 2.01e-4 | 1.74e-4 |
1-3 MeV | 1.07e-3 | 1.283e-3 | 5.633e-5 | 1.68e-4 | 1.69e-4 |
3-10 MeV | 3.98e-4 | 2.42e-4 | 2.48e-5 | 7.3e-5 | 7.43e-4 |