Change request #2758
CTA background rates should be consistently per ontime
| Status: | Closed | Start date: | 11/16/2018 | |
|---|---|---|---|---|
| Priority: | Urgent | Due date: | ||
| Assigned To: | % Done: | 100% | ||
| Category: | - | |||
| Target version: | 1.6.0 | |||
| Duration: |
Description
So far background rates are assumed per livetime for IRF templates and analytical models and per ontime for a background cube. This should be changed to per ontime to be also consistent with the open gamma data format.
Recurrence
No recurrence.
History
#1
Updated by Knödlseder Jürgen almost 8 years ago
- Status changed from New to Pull request
- % Done changed from 0 to 100
I changed all relevant methods related to the CTA background modeling. No deadtime correction is applied anymore.
#2
Updated by Knödlseder Jürgen almost 8 years ago
- Status changed from Pull request to Closed
Merged into devel.