Updated over 11 years ago by Knödlseder Jürgen

COMPTEL Crab validation

This page summarizes analysis results obtained using GammaLib on the Crab.

VP 1 validation

The interface has been validated using the COMPTEL data from Viewing Period 1. This observation was a 14 days pointing on the Crab. The analysis has been performed using GammaLib-00-07-00. The background has been modeled using a Phibar-fitted DRG file. This is only a crude background model, which may explain the discrepancy between nominal and fitted fluxes. The quoted sensitivities and the sensitivity derived by multiplying the statistical uncertainty by a factor of 3 are pretty close. Units are ph/cm2/s.

Energy Nominal flux (1) Fitted flux Error Quoted sensitivity (2) Sensitivity (3*error)
0.7-1 MeV 5.55e-4 8.55e-4 5.80e-5 2.01e-4 1.74e-4
1-3 MeV 1.07e-3 1.283e-3 5.633e-5 1.68e-4 1.69e-4
3-10 MeV 3.98e-4 2.42e-4 2.48e-5 7.3e-5 7.43e-4
10-30 MeV 1.06e-4 5.03e-5 8.28e-6 2.8e-5 2.48e-5
References:

COMPTEL_catalogue.pdf (3.91 MB) Preview Knödlseder Jürgen, 01/14/2013 12:19 PM

Crab_analysis.pdf (386 KB) Preview Knödlseder Jürgen, 01/14/2013 12:19 PM

Also available in: PDF HTML TXT